Pressure sensor with display PN2293

  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
  • Description

    Description

    PN-025-REN14-MFRKG/US/ /V

    Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Measuring range
    -1…25 bar -14.5…362.5 psi -0.1…2.5 MPa
    Process connection threaded connection 1/4″ NPT internal thread Application Special feature Gold-plated contacts Measuring element ceramic-capacitive pressure measuring cell Application for industrial applications Media liquids and gases Medium temperature [°C] -25…80 Min. bursting pressure
    350 bar 5075 psi 35 MPa
    Pressure rating
    150 bar 2175 psi 15 Mpa
    Vacuum resistance [mbar] -1000 Type of pressure relative pressure; vacuum MAWP (for applications according to CRN)
    70 bar 1015 psi 7 MPa
    Electrical data Operating voltage [V] 18…30 DC; (to SELV/PELV) Current consumption [mA] < 35 Min. insulation resistance [MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] 0.3 Integrated watchdog yes Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Outputs Total number of outputs 2 Output signal switching signal; analogue signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / normally closed; (parameterisable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 250 Switching frequency DC [Hz] < 500 Number of analogue outputs 1 Analogue current output [mA] 4…20; (scalable 1:5) Max. load [Ω] 500 Analogue voltage output [V] 0…10; (scalable 1:5) Min. load resistance [Ω] 2000 Short-circuit protection yes Type of short-circuit protection pulsed Overload protection yes Measuring/setting range Measuring range
    -1…25 bar -14.5…362.5 psi -0.1…2.5 MPa
    Analogue start point
    -1…20 bar -14.5…290 psi -0.1…2 MPa
    Analogue end point
    4…25 bar 58…362.5 psi 0.4…2.5 MPa
    Factory setting / CMPT = 2 Set point SP
    -0.85…25 bar -12…362.5 psi -0.085…2.5 MPa
    Reset point rP
    -0.95…24.9 bar -13.5…361 psi -0.095…2.49 MPa
    Min. difference between SP and rP
    0.15 bar 1.5 psi 0.015 MPa
    In steps of
    0.05 bar 0.5 psi 0.005 MPa
    Status_B High Resolution / CMPT = 3 Set point SP
    -0.84…25 bar -12.2…362.6 psi -0.084…2.5 MPa
    Reset point rP
    -0.95…24.9 bar -13.7…361.1 psi -0.095…2.49 MPa
    Min. difference between SP and rP
    0.11 bar 1.5 psi 0.011 MPa
    In steps of
    0.01 bar 0.1 psi 0.001 MPa
    Accuracy / deviations Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1) Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1) Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months) Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0…80 °C) Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0…80 °C) Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% Response times Response time [ms] < 1.5 Delay time programmable dS, dr [s] 0…50 Damping process value dAP [s] 0…4 Damping for the analogue output dAA [s] 0…4 Max. response time analogue output [ms] 3 Software / programming Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 SIO mode yes Required master port type A; (wenn PIN 2 nicht verbunden: B) Supported DeviceIDs
    Type of operation DeviceID
    Factory setting / CMPT = 2 472
    Status_B High Resolution / CMPT = 3 988
    Note
    For further information please see the IODD PDF file under “Downloads”
    Factory setting / CMPT = 2 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis Min. process cycle time [ms] 2.3 IO-Link resolution pressure [bar] 0.01 IO-Link process data (cyclical)
    function bit length
    pressure 14
    binary switching information 2
    IO-Link functions (acyclical) application specific tag Status_B High Resolution / CMPT = 3 Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) Min. process cycle time [ms] 3 IO-Link resolution pressure [bar] 0.01 IO-Link process data (cyclical)
    function bit length
    pressure 16
    device status 4
    binary switching information 2
    IO-Link functions (acyclical) application specific tag Operating conditions Ambient temperature [°C] -25…80 Storage temperature [°C] -40…100 Protection IP 65; IP 67 Tests / approvals EMC
    DIN EN 61000-6-2
    DIN EN 61000-6-3
    Shock resistance
    DIN EN 60068-2-27 50 g (11 ms)
    Vibration resistance
    DIN EN 60068-2-6 20 g (10…2000 Hz)
    MTTF [years] 138 UL approval
    UL Approval no. J012
    Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request Mechanical data Weight [g] 223.5 Materials stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC Materials (wetted parts) stainless steel (1.4404 / 316L); AI2O3 (96%; ceramics); FKM Min. pressure cycles 100 million Tightening torque [Nm] > 50; (depends on lubrication, seal and pressure rating) Process connection threaded connection 1/4″ NPT internal thread Restrictor element integrated no (can be retrofitted) Displays / operating elements Display
    Display unit 3 x LED, green (bar, psi, MPa)
    switching status 2 x LED, yellow
    measured values alphanumeric display, red/green 4-digit
    Remarks Pack quantity 1 pcs. Electrical connection Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
    Shipping and delivery
     

    WE DELIVER WORLDWIDE

    • Delivery time depends on whether the product is in our warehouse. If so, super fast shipping is available. Otherwise, the delivery terms depend on the conditions provided by the manufacturer.
    • For your convenience, we take care of getting the best price and delivering the goods on time.
    • We cooperate with various types of carriers around the world. Super fast delivery is available.

    SEARCHING FOR SOMETHING SPECIAL? LET'S TALK

    Address: Klaipėdos st. 79A, Panevėžys
    Company code: 300629576
    VAT code: LT100002971111
    Bank: SC 'Citadele banka'
    Bank code: 72900
    Account number: LT557290099087515081

    WORLDWIDE SHIPPING

    WE DELIVER ALL OTHER THE WORLD

    (EXCEPT, RUSSIA, OBVIOUSLY)

    BEST PRODUCTS

    WE SUPPLY PRODUCTS DIRECTLY FROM BEST RATED PRODUCERS IN THE WORLD

    SUPPORT

    OUR TEAM IS READY TO RESPOND AS SOON AS POSSIBLE AND HELP CHOOSE PRODUCT YOU NEED

    100% SAFE & SECURE

    FOR MORE THAN 15 YEARS WE ARE IN THIS INDUSTRY AND GAINED THE TRUST OF COSTUMERS WORLDWIDE