    INE2004DN/1D/1G/2G

    Product characteristics Electrical design NAMUR Output function 2 x normally closed Sensing range [mm] 4 Housing rectangular Dimensions [mm] 33 x 60 x 92 Electrical data Connection to switching amplifiers yes Switching amplifiers connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW Operating voltage [V] 8.2 DC; (1kΩ) Supply voltage DC [V] 7.5…15; (when used outside the hazardous area) Current consumption [mA] < 1; (disabled; conductive: > 2,1) Protection class III Actuator wiring connection to certified intrinsically safe circuits of solenoid valves with the max. values: U = 28 V / I = 250 mA / P = 750 mW (bis 40 °C) / P = 650 mW (bis 70 °C); (When used in gas atmospheres (group II) the following maximum values are permitted: U = 28 V / P = 1,1 W; These values must not be exceeded.) Outputs Electrical design NAMUR Output function 2 x normally closed Switching frequency DC [Hz] 500 Overload protection yes Detection zone Sensing range [mm] 4 Real sensing range Sr [mm] 4 ± 10 % Operating distance [mm] 0…3.25 Accuracy / deviations Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 Hysteresis [% of Sr] 1…15 Switch point drift [% of Sr] -10…10 Operating conditions Ambient temperature [°C] -25…70 Protection IP 65; IP 67 Tests / approvals Approval BVS 14 ATEX E 005 X; IECEx BVS 14.0005X ATEX marking II 1G Ex ia IIB T4 Ga Ta: -25…70 °C II 2G Ex ia IIC T4 Gb Ta: -25…70 °C II 1D Ex ia IIIB T135 °C Da Ta: -25…70 °C EMC
    EN 60947-5-6
    Vibration resistance
    10…55 Hz (1 mm)
    Shock resistance
    30 g (11 ms)
    MTTF [years] 1257 Safety classification Max. internal capacitance [nF] 60; (per intrinsically safe circuit) Max. internal inductance [µH] 130; (per intrinsically safe circuit) Mechanical data Weight [g] 183 Housing rectangular Mounting non-flush mountable Dimensions [mm] 33 x 60 x 92 Materials housing: PA Displays / operating elements Display
    switching status 2 x LED, yellow
    Accessories Items supplied
    socket head screws: 2 x M5 x 16
    socket head screws: 2 x M3 x 25
    Remarks Remarks
    The unit is not approved for safety-related tasks in the field of operator protection.
    Pack quantity 1 pcs. Electrical connection Connection terminal strip in the terminal chamber: …2.5 mm²; Cable gland: M20 X 1.5
    Shipping and delivery
     

    WE DELIVER WORLDWIDE

    • Delivery time depends on whether the product is in our warehouse. If so, super fast shipping is available. Otherwise, the delivery terms depend on the conditions provided by the manufacturer.
    • For your convenience, we take care of getting the best price and delivering the goods on time.
    • We cooperate with various types of carriers around the world. Super fast delivery is available.

    SEARCHING FOR SOMETHING SPECIAL? LET'S TALK

    Address: Klaipėdos st. 79A, Panevėžys
    Company code: 300629576
    VAT code: LT100002971111
    Bank: SC 'Citadele banka'
    Bank code: 72900
    Account number: LT557290099087515081

    WORLDWIDE SHIPPING

    WE DELIVER ALL OTHER THE WORLD

    (EXCEPT, RUSSIA, OBVIOUSLY)

    BEST PRODUCTS

    WE SUPPLY PRODUCTS DIRECTLY FROM BEST RATED PRODUCERS IN THE WORLD

    SUPPORT

    OUR TEAM IS READY TO RESPOND AS SOON AS POSSIBLE AND HELP CHOOSE PRODUCT YOU NEED

    100% SAFE & SECURE

    FOR MORE THAN 15 YEARS WE ARE IN THIS INDUSTRY AND GAINED THE TRUST OF COSTUMERS WORLDWIDE