Description
IVE2020-FBKA
Product characteristics |
Output function |
normally open / normally closed; (selectable) |
Sensing range [mm] |
20 |
Housing |
rectangular |
Dimensions [mm] |
40 x 40 x 118 |
Electrical data |
Operating voltage [V] |
24…250 AC / 24…230 DC |
Protection class |
II |
Reverse polarity protection |
yes |
Outputs |
Output function |
normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] |
5 |
Max. voltage drop switching output AC [V] |
8 |
Minimum load current [mA] |
5 |
Max. leakage current [mA] |
1.5 |
Permanent current rating of switching output AC [mA] |
500 |
Permanent current rating of switching output DC [mA] |
500 |
Switching frequency AC [Hz] |
30 |
Switching frequency DC [Hz] |
100 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Detection zone |
Sensing range [mm] |
20 |
Real sensing range Sr [mm] |
20 ± 10 % |
Operating distance [mm] |
0…16.2 |
Accuracy / deviations |
Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] |
1…10 |
Switch point drift [% of Sr] |
-10…10 |
Operating conditions |
Ambient temperature [°C] |
-25…85 |
Note on ambient temperature |
for UL application: …70 °C |
|
Max. height above sea level [m] |
2000 |
Protection |
IP 67 |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
8 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-6 HF conducted |
15 V |
EN 55011 |
Class A |
|
Vibration resistance |
EN 60068-2-6 Fc |
10 g (10…2000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
|
Shock resistance |
EN 60068-2-27 Ea |
30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
|
Continuous shock resistance |
EN 60068-2-27 |
40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
|
Fast temperature change |
EN 60068-2-14 Na |
TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
|
MTTF [years] |
272.6 |
UL approval |
Ta |
0…70 °C |
Enclosure type |
Type 1 |
File number UL |
E174191 |
|
Notes |
For use in NFPA 79 applications only |
Mechanical data |
Weight [g] |
268 |
Housing |
rectangular |
Mounting |
flush mountable |
Dimensions [mm] |
40 x 40 x 118 |
Materials |
PA 6.6; diecast zinc epoxy coated; sensing face: PA 6.6; LED window: PA; screws: stainless steel stainless steel (1.4305 / 303) |
Displays / operating elements |
Display |
switching status |
1 x LED, yellow |
operation |
1 x LED, green |
|
Electrical connection |
Required protection |
≤ 3 A und ≥ 300 V AC/DC |
Remarks |
Remarks |
5 positions of the active zone possible |
Cable gland (E11270) to be ordered separately |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
terminals: …2.5 mm²; Cable gland: M20 X 1.5 |