Description
Plug, nom. voltage: 800 V, nominal current: 32 A, number of positions: 13, connection method: Spring-cage connection, Rated cross section: 4 mm2, cross section: 0.08 mm2- 6 mm2, color: gray
Product type | Terminal plug |
Number of positions | 13 |
Pitch | 6.2 mm |
Insulation characteristics | |
Overvoltage category | III |
Degree of pollution | 3 |
Rated surge voltage | 8 kV |
Nominal cross section | 4 mm² |
Stripping length | 8 mm … 10 mm |
Internal cylindrical gage | A4 |
Connection in acc. with standard | IEC 61984 |
Conductor cross section solid | 0.08 mm² … 6 mm² |
Cross section AWG | 28 … 10 (converted acc. to IEC) |
Conductor cross section flexible | 0.08 mm² … 4 mm² |
Conductor cross section, flexible [AWG] | 28 … 10 (converted acc. to IEC) |
Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) | 0.14 mm² … 4 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² … 4 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² … 1 mm² |
Nominal current | 32 A |
Maximum load current | 32 A (with 6 mm² conductor cross section) |
Nominal voltage | 800 V |
Nominal cross section | 4 mm² |
Width | 80.6 mm |
Height | 41.5 mm |
Length | 21 mm |
Pitch | 6.2 mm |
Color | gray |
Flammability rating according to UL 94 | V0 |
Insulating material group | I |
Insulating material | PA |
Static insulating material application in cold | -60 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Ambient conditions | |
Ambient temperature (operation) | -60 °C … 105 °C (max. short-term operating temperature RTI Elec.) |
Ambient temperature (storage/transport) | -25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Ambient temperature (assembly) | -5 °C … 70 °C |
Ambient temperature (actuation) | -5 °C … 70 °C |
Permissible humidity (storage/transport) | 30 % … 70 % |
Connection in acc. with standard | IEC 61984 |
Item number | 3043718 |
Packing unit | 10 pc |
Minimum order quantity | 1 pc |
Note | Made to Order (non-returnable) |
Sales Key | BE2 |
Product Key | BE2144 |
Catalog Page | Page 345 (C-1-2019) |
GTIN | 4017918956349 |
Weight per Piece (including packing) | 55.04 g |
Weight per Piece (excluding packing) | 55.04 g |
Customs tariff number | 85366990 |
Country of origin | PL |
ECLASS
ECLASS-9.0 | 27141151 |
ECLASS-10.0.1 | 27141151 |
ECLASS-11.0 | 27141151 |
ETIM
ETIM 8.0 | EC002021 |
UNSPSC
UNSPSC 21.0 | 39121400 |
Large-surface labeling option|Practical coding option|Tested for railway applications