Description
MN38010-BPKG/UC/-H
Product characteristics |
Electrical design |
PNP |
Output function |
2 x OSSD, 1 x PNP |
Sensing range [mm] |
12; (with defined actuator) |
Housing |
rectangular |
Dimensions [mm] |
72 x 18 x 25 |
Application |
Design |
uniquely fully coded target |
Type of operation |
permanent operation |
Radio approval for |
USA; Canada; Australia; EU/RED; China; Singapore |
Note on radio approval |
The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”. |
|
Electrical data |
Operating voltage [V] |
20.4…26.4 DC |
Rated insulation voltage [V] |
32 |
Operating current [mA] |
40…700 |
No-load current [mA] |
30 |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Max. power-on delay time [ms] |
1500 |
Outputs |
Electrical design |
PNP |
Output function |
2 x OSSD, 1 x PNP |
Max. leakage current [mA] |
0.5 |
Permanent current rating of switching output DC [mA] |
50 |
Switching frequency DC [Hz] |
1 |
Output data |
interface type C class 2 |
Short-circuit protection |
yes |
Overload protection |
yes |
Max. capacitive load CL_max [nF] |
200 |
Detection zone |
Sensing range [mm] |
12; (with defined actuator) |
Safe switching-off distance s(ar) [mm] |
16 |
Accuracy / deviations |
Hysteresis [%] |
20 |
Repeatability analogue output [%] |
≤ 10; (% Sn) |
Response times |
Response time to safety request [ms] |
160 |
Response time when approaching the enable zone [ms] |
600 |
Risk time (response time for safety-related faults) [ms] |
10 |
Operating conditions |
Applications |
class C to EN 60654-1 weatherproof application |
Ambient temperature [°C] |
-25…70 |
Note on ambient temperature |
operational life ≤ 87600 h |
|
Ambient temperature [°C] |
10…40 |
Note on ambient temperature |
operational life ≤ 175200 h |
|
Max. relative air humidity [%] |
briefly: 5…95 %; permanent: 5…70 % |
Air pressure [kPa] |
80…106 |
Max. height above sea level [m] |
2000 |
Ionising radiation |
not permissible |
Salt spray |
no |
Protection |
IP 67; IP 69K; (protected cable laying) |
Tests / approvals |
EMC |
|
Shock resistance |
EN 60068-2-27 |
30 g (11 ms) |
|
Vibration resistance |
IEC 60068-2-6 |
10 g (10…55 Hz) |
|
Safety classification |
Complies with the requirements |
ISO 13849-1: 2015 category 4, PL e |
IEC 62061 SIL 3 |
|
Mission time TM [h] |
≤ 175200 |
Mission time TM (additional indication) |
|
PFH [1/h] |
1,5E-09 |
Mechanical data |
Weight [g] |
330 |
Housing |
rectangular |
Mounting |
non-flush mountable |
Dimensions [mm] |
72 x 18 x 25 |
Materials |
PA |
Tightening torque [Nm] |
0.8…2 |
Displays / operating elements |
Display |
function |
1 x LED, (ACT) |
input |
1 x LED, (IN) |
Output |
1 x LED, (OUT) |
operation |
1 x LED, (PWR) |
|
Accessories |
Items supplied |
uniquely fully coded target |
washers: 4 |
cover caps: 8 |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Cable: 2 m, PVC; 8 x 0.34 mm² |