Technical data at 3 x 400 V AC: Nominal output current: 1x 5 A @ 4kHz / 1x 4.5 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 3.5 KVA. Without brake resistor. Option: Without Safety module technology, with EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 2x 5 A @ 4kHz / 2x 4.5 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 2x 3.5 KVA. Without brake resistor. Option: Safety module SR6 (STO using terminals) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 2x 5 A @ 4kHz / 2x 4.5 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 2x 3.5 KVA. Without brake resistor. Option: Safety module SY6 (STO and SS1 using FSoE) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 2x 5 A @ 4kHz / 2x 4.5 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 2x 3.5 KVA. Without brake resistor. Option: Without Safety module technology, with EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 1x 12 A @ 4kHz / 1x 10 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 8.3 KVA. Without brake resistor. Option: Safety module SR6 (STO using terminals) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 1x 12 A @ 4kHz / 1x 10 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 8.3 KVA. Without brake resistor. Option: Safety module SY6 (STO and SS1 using FSoE) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 1x 12 A @ 4kHz / 1x 10 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 8.3 KVA. Without brake resistor. Option: Without Safety module technology, with EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 2x 12 A @ 4kHz / 2x 10 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 2x 8.3 KVA. Without brake resistor. Option: Safety module SR6 (STO using terminals) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 2x 12 A @ 4kHz / 2x 10 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 2x 8.3 KVA. Without brake resistor. Option: Safety module SY6 (STO and SS1 using FSoE) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 2x 12 A @ 4kHz / 2x 10 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 2x 8.3 KVA. Without brake resistor. Option: Without Safety module technology, with EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 1x 22 A @ 4kHz / 1x 20 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 16.6 KVA. Without brake resistor. Option: Safety module SR6 (STO using terminals) and EtherCat...
Technical data at 3 x 400 V AC: Nominal output current: 1x 22 A @ 4kHz / 1x 20 A @ 8kHz. Imax: 210% for 2s / 250% for 2s. Apparent power: 16.6 KVA. Without brake resistor. Option: Safety module SY6 (STO and SS1 using FSoE) and EtherCat...