NJ2-11-N-G-V1-Y194329
- Brand: Pepperl Fuchs
- Model: NJ2-11-N-G-V1-Y194329
Datasheet excerpt: Technical data of NJ2-11-N-G-V1-Y194329General specifications
- Switching function: Normally closed (NC)
- Output type: NAMUR
- Rated operating distance: 2 mm
- Installation: flush
- Assured operating distance: 0 ... 1.62 mm
- Actual operating distance: 1.8 ... 2.2 mm
- Reduction factor r_Al: 0.4
- Reduction factor r_Cu: 0.3
- Reduction factor r_304: 0.85
- Output type: 2-wireNominal ratings
- Nominal voltage: 8.2 V (R_i approx. 1 kΩ)
- Switching frequency: 0 ... 3000 Hz
- Hysteresis: 0.5 ... 3.5 typ. 2 %
- Current consumption:
- Measuring plate not detected: min. 3 mA
- Measuring plate detected: ≤ 1 mAFunctional safety related parameters
- MTTF_d: 5887 a
- Mission Time (T_M): 20 a
- Diagnostic Coverage (DC): 0 %Compliance with standards and directives
- Standard conformity:
- NAMUR: EN 60947-5-6:2000, IEC 60947-5-6:1999
- Standards: EN 60947-5-2:2007, EN 60947-5-2/A1:2012, IEC 60947-5-2:2007, IEC 60947-5-2 AMD 1:2012Approvals and certificates
- IECEx approval:
- Equipment protection level Ga: IECEx PTB 11.0037X
- Equipment protection level Gb: IECEx PTB 11.0037X
- Equipment protection level Da: IECEx PTB 11.0037X
- Equipment protection level Mb: IECEx PTB 11.0037X
- ATEX approval:
- Equipment protection level Ga: PTB 00 ATEX 2048 X
- Equipment protection level Gb: PTB 00 ATEX 2048 X
- Equipment protection level Da: PTB 00 ATEX 2048 X
- UL approval:
- Ordinary Location: E87056
- Hazardous Location: E501628
- Control drawing: 116-0452
- ANZEx: 18.3018XAmbient conditions
- Ambient temperature: -25 ... 100 °C (-13 ... 212 °F)Mechanical specifications
- Connection type: Connector plug
- Housing material: Stainless steel 1.4305 / AISI 303
- Sensing face: PVDF
- Degree of protection: IP68
- Connector:
- Threading: M12 x 1
- Number of pins: 4General information
- Use in the hazardous area: see instruction manualsClassifications
- System: ECLASS 11.0, Classcode: 27270101
- System: ECLASS 10.0.1, Classcode: 27270101
- System: ECLASS 9.0, Classcode: 27270101
- System: ECLASS 8.0, Classcode: 27270101
- System: ECLASS 5.1, Classcode: 27270101
- System: ETIM 8.0, Classcode: EC002714
- System: ETIM 7.0, Classcode: EC002714
- System: ETIM 6.0, Classcode: EC002714
- System: ETIM 5.0, Classcode: EC002714
- System: UNSPSC 12.1, Classcode: 39121550
WE DELIVER WORLDWIDE
- Delivery time depends on whether the product is in our warehouse. If so, super fast shipping is available. Otherwise, the delivery terms depend on the conditions provided by the manufacturer.
- For your convenience, we take care of getting the best price and delivering the goods on time.
- We cooperate with various types of carriers around the world. Super fast delivery is available.